SZ7251
SZ7251 Auto Cleaning Flow Cell
SZ7251 Auto clean flow cells for ORP, residual chlorine, dissolved ozone.
This cell is designed for the in-line or in-flow continuous measurement of ORP, residual chlorine or dissolved ozone in solution. The measuring sensor is inserted in the holder of the cell, which protects the body and places the sensing part in the right position into the cell.
The sample inlet flow will create a continuous movement of the internal balls whose contact with the sensing part of the sensor will perform a self-cleaning action. The sample inlet pressure must be constant in order to get a continuous flow necessary to obtain stable and reliable measuring.
The package includes:
- Plastic tube for the connection to the sample
- Fixing clamp
- Spare balls.
The sample inlet pressure must be constant in order to get a continuous flow necessary to obtain stable and reliable measuring.
SZ7251 Flow Cell Specifications
-
Specifications
Transparent Body: Acrylic
Holder: PVC
O Ring: NBR and fluoridated elastomer
Fittings: Polypropylene
Tubing: Polythene
Balls: N° 20 into the body
Inlet/Outlet: 1/8 " fittings
Diameter: 40 mm max
Length: 150 mm max
Flow: 15/40 liter/hour constant
Temperature: 0/50 °C
Connecting Tubing: Diameter 4X6 mm. L=5 m